Principle of the sensor:
|
Carrier catalyzing type
|
|
Explosion prevention level:
|
Ex dII CT6 (including ethyne )
|
|
Working voltage
|
DC24V ±15%
|
|
Working current:
|
50 mA
|
|
Detecting range:
|
0 – 99% LEL
|
|
Indication error:
|
±3% LEL (F.S)
|
|
Weight:
|
1kg
|
|
Working humidity:
|
≤ 93 ± 2% relative humidity
|
|
Structure dimension:
|
85 × 90 × 110mm (length ×width ×height )
|
|
Calibration gas:
|
calibrated with a standard gas of mixing methane and air
|
|
Anti-toxicity:
|
sensor can resist H2S with 100ppm (if need, please indicate when order)
|
|
Non-working display :
|
auto-display when sensor cannot work normally (optional installing)
|
|
Display mode:
|
LED digital display (optional installing)
|
|
Calibration of infrared remote controller:
|
≥ 15 meters 4 – 20 mA standard signal output
|
|
Output mode:
|
① voltage signal output (matched with QB-DAP2000 wall-mounting combustible gas alarm controller)
② 4-20mA standard signal output (matched with DAP2102-GP1 built-in toxic gas alarm controller; QB-DAP2000 wall-mounting combustible gas alarm controller; DCS system )
③ normal-open connection (matched with different kinds of fire alarm systems)
|